I have done some moisture monitoring with Watermarks in the past and now
have use of a Diviner 2000 from Sentek. I wish to be able to compare
previous years data to current data. One problem I see off the bat is that
the Watermarks read in centibars while the D2K reads in mm of water in a
profile. I am curious how I might easily convert between the two without
doing some gravimetric testing to establish the soil true capacity. Even
then, without testing through many matric potentials to establish a proper
curve, how could I be sure that each unit was responding to soil moisture
in a similar fashion??
Tom Thomson                     Northwest Agricultural Consulting
1275 Oak Villa Road	                   tomt@teleport.com
Dallas, Oregon 97338                       Phone/FAX 503-623-0468

"The only difference between a problem and a solution is that 
everyone understands the solution."         Charles Kettering

[Why not compare the two sensors directly in a test bed and allow it to dry
across the range? Bruce]