|
archiving of SOWACS proudly sponsored by |
![]() |
NOTE: To get off this list, send email to majordomo@aqua.ccwr.ac.za with the body of the message containing the line: unsubscribe sowacs The standard road gauges manufacturerd by CPN (MC-1 DR/MC-3), Troxler (3430/3430) or Humboldt Scientific (5001C/5001EZ) should be able to perform this task with both hands tied! as these guages read moisture in backscatter mode some commonsense method may be required to deal with the underlying surface (if any). recards. carlton weber development manager geoquip carlton@geoquip.co.za owner-sowacs@aqua.ccwr.ac.za wrote: > > NOTE: To get off this list, send email to majordomo@aqua.ccwr.ac.za > with the body of the message containing the line: > unsubscribe sowacs > > [Anyone have any ideas for this difficult application? > Please reply via the list. Bruce] > > To whom it may concern, > > We have an application for the measurment of water content in in a sheet of > paper board that is 12mm thick and 8' x 12' in size. The application is an > industrial one where the water content in different parts of the sheet is > required to be known at the exit of the paper board dryiers. > > Hoping to hear from you soon, > > Christian Martel, P. Eng. > Senior Project Engineer > IndustrlElec International