archiving of SOWACS proudly sponsored by |
![]() |
NOTE: To get off this list, send email to majordomo@aqua.ccwr.ac.za with the body of the message containing the line: unsubscribe sowacs Dear Dr Camilo L. T. Andrade My PhD work may be of some help to you as far as runoff measurements are concerned. I indeed developed a methodology to measure instantaneous runoff flow on small plots (20 m2) that was based on pressure sensors in drums. I send you an extract of my manuscript written in french !!! If you find problems to understand some details, please contact me. Best regards, Antoine Findeling [Available on http://www.sowacs.com/runoff/RunoffFindeling.pdf the first paragraph of which I append here.. Bruce] >> Ce chapitre est dÈdiÈ ý líanalyse des effets du semis direct avec paillis de rÈsidus sur les phÈnomËnes physiques impliquÈs dans le ruissellement : interception de la pluie par la culture et par le paillis, infiltra-tion de líeau dans le sol, rÈtention díeau en surface et Ècoulement du ruissellement sur le sol. Le travail a pour objectifs, díune part la comprÈhension et la quantification des processus gouvernant le ruisselle-ment en prÈsence de paillis, díautre part la formalisation de ces processus dans un modËle simple ý base physique. Ce modËle sera intÈgrÈ par la suite dans un modËle de fonctionnement global (chapitre 6). > >Date: Tue, 13 Nov 2001 18:33:38 GMT > >From: owner-sowacs@aqua.ccwr.ac.za > >X-Authentication-Warning: aqua.ccwr.ac.za: majordom set sender to > owner-sowacs using -f > >Subject: Runoff and percolation flow meter > >Sender: owner-sowacs@aqua.ccwr.ac.za > > > >NOTE: To get off this list, send email to majordomo@aqua.ccwr.ac.za > >with the body of the message containing the line: > >unsubscribe sowacs > > > >Dear members, > > > >I would like to know if someone else has experience on automatically > >measuring runoff flow from erosion parcels. We are currently collecting the > >volume daily and manually measuring it. Of course the water comes dirty > >with soil and maybe some debris and not all flow meter would work on this > >situation. In addition any ideas to automatically measure percolation, > >which is in our case a small flow rate. > > > >Regards, > > > >Camilo L. T. Andrade > >Embrapa Maize and Sorghum > >Rod. MG 424, Km 65, P.O. Box 151 > >35701-970 - Sete Lagoas, MG > >Brazil > >Tel +55 31 3779 1235 > >Fax +55 31 3779 1088 --------------------------------------------------------------- Antoine Findeling CIRAD, Laboratoire Solemi - TA 40/01 - Avenue Agropolis 34398 Montpellier Cedex 5 - France Tel. : 04.67.61.71.72 / Fax : 04.67.61.56.42 Tel. personnel : 04.67.58.32.72 http://www.cirad.fr/ ---------------------------------------------------------------