Yeh Ive seen something similar in flooded sugarcane where tensiometers
connected to a presure transducer show positve readings during flooding
events. The results tend to be only slightly positive and are a direct
result of the posite head or the amount of water pushing down on the
tensiometer tip.
----- Original Message -----
> > Dear subscribers to SoWaCs,
> >
> >
> >I'm working on Wetland hydrology in the Seine valley (France). To
> >investigate unsaturated zone
> >I used SDEC tensiometers and the SDEC portable electronic readout unit.
> >I've done two years of measurements and it worked very good except during
> >flood events (site was
> >covered by a 30cm thick watershed sometimes during the study period).
> >During those events, the depression measured by the tensiometer was
positive !
> >Does anybody encount the same problem ??
> >
> NO PROBLEM. LOOKS LIKE YOU MEASURED A POSITIVE HEAD DURING SATURATED
> CONDITIONS.
>
> =======================================
> Gary Hart