From: Marty Grogan (ges) To: SOWACS@aqua.ccwr.ac.za Date: Saturday, July 6, 1996 7:21 pm Subject: Re:Temperature dependance of ... Many instrumentation systems exhibit a cyclical temperaturevariation which depends on thermal mass as well as static variation with ambient temperature. The cyclical variation can be factored by averagingmaximums and minimums over the cycle window. These cycles can be as shortas minutes or as long as hours. Question: How much variation of concern occurs because of cyclingvs. static variation? M. G.